The LGR-ICOS™ GLA331-GGA Greenhouse Gas Analyser EP Rackmount provides you with precise, fast measurement of CH₄, CO₂ and H₂O in ambient air.
As with all ABB-LGR analysers, the GLA331-GGA utilises Off-Axis Integrated Cavity Output Spectroscopy (OA-ICOS). A patented, fourth-generation cavity enhanced technique, OA-ICOS has many advantages over older and more delicate techniques such as Cavity Ring-Down Spectroscopy (CRDS), and conventional laser spectroscopy.
In addition to providing extreme sensitivity due to the folded absorption path, and a wide dynamic range due to the direct absorption-based measurement, OA-ICOS is an inherently robust technique. Due to the off-axis alignment of the optics, LGR analysers are far less sensitive to temperature variations, vibrations, shocks, and dust than similar cavity-based methods. This also means the optics can be cleaned by the user, without needing an expensive return to the factory.
ABB-LGR analysers require no consumables, no carrier gases, and no regular recalibrations. The versatility and sturdiness of the OA-ICOS measurement cell enables reliable measurements in a wide range of applications and environments. ABB-LGR employs the OA-ICOS technique to measure a wide variety of gases and isotopes, in both ultra-precise rackmount laboratory instruments, and portable gas analysers for the field. All ABB-LGR analysers supplied by Enviro Technology are backed by a 2-year manufacturer warranty, and responsive support from our expert team of UK-based technicians.
Servicing
Datasheet
LGR-ICOS™ GLA331-GGA Greenhouse Gas Analyser EP Rackmount
Specifications
Precision (1s, 1 sec / 10 sec / 100 sec)
- CH₄: 0.6 ppb / 0.2 ppb / 0.1 ppb
- CO₂: 150 ppb / 50 ppb / 20 ppb
- H₂O: 150 ppm / 50 ppm / 17 ppm
Maximum Drift (15 min average, at STP, over 24 hrs)
- CH₄: <3 ppb
- CO₂: <0.2 ppm
Linear measurement ranges (meets all specifications)
- CH₄: Up to 100 ppm (10 000 ppm with external range)
- CO₂: Up to 20000 ppm
- H₂O: Up to 30000 ppm
Measurement rate
- 0.01 – 1 Hz (user selectable)
- Up to 10 Hz with Fast flow option
Flow time response
- <10 seconds (1/e)
- 0.1 second (1/e) with external dry scroll pump ACC-DS35
Sampling conditions
- Operating temperature: 5 – 45 °C
- Ambient humidity: <99% relative humidity non-condensing
Data outputs
Wi-Fi, Ethernet, USB, MIU connection (8/16 ports), Serial (RS232)
Power requirements
- 110/240 VAC
- 170 W (steady state)
- Max 420 W with external ACC-DP4H
Dimensions
(H x W x D): 40 x 48 x 61 cm (15.75 x 19 x 24 in.)
Weight
40 kg (88 lbs)